ChirpStack
Applies to SiteSync StandardEnterprise Management
ChirpStack is an open-source LoRaWAN network server. The values below assume default ChirpStack settings — confirm with whoever set up your instance if it has been customized.
MQTT connection
Section titled “MQTT connection”| Field | Value |
|---|---|
| Broker URL or IP address | The URL you use to access your ChirpStack instance, without http://. |
| Port | 1883 (default). |
| MQTT topic | application/{chirpstack-application-id}/device/+/event/up — replace {chirpstack-application-id} with your application’s ID. |
| Username / Password | Not required by default. SiteSync recommends enabling authentication to secure your broker data. |
Join Server (API) connection
Section titled “Join Server (API) connection”| Field | Value |
|---|---|
| URL | The URL of your ChirpStack instance, including port 8090. |
| Application ID | The ChirpStack application to sync devices into. Found on the application’s main page. |
| Device Profile ID | The default device profile applied to synced devices. Found on a device profile’s main page. |
| API Token | Generated in ChirpStack under API Keys. |