SiteSync 1.1.0
Applies to Enterprise ManagementField App
Release metadata
Section titled “Release metadata”| Release | 1.1.0 |
| Release date | October 23, 2026 |
| Release type | Feature release |
| Previous release | 1.0.1 |
| Affected projects | SiteSync Source, Enterprise Management, Field App |
| Primary scope | Device archive and guided sensor replacement, audit log, commissioning (In testing), site maps, sticky filters, device profile fixes, dashboard accuracy, and fixes raised in weekly reviews |
Summary
Section titled “Summary”SiteSync 1.1.0 builds on 1.0.1 with the device lifecycle features discussed in the weekly syncs.
- Device lifecycle. Devices can be archived and un-archived, and a failed or replaced sensor can be swapped through a guided flow that keeps its tag path, history, and configuration.
- Accountability. A configurable audit log records who did what: device changes, downlinks, profile and connection edits, and sign-ins.
- Commissioning. Devices still being commissioned can be marked In testing, so they report normally but stay out of dashboards and counts until they go live.
- Field use. Filters persist across navigation, sites can be viewed on a map, and dashboards report device and alarm counts accurately.
Highlights
Section titled “Highlights”- Archive and un-archive devices, with an Archived Devices page (search, filters, CSV export) in Enterprise Management and the Field App.
- Guided sensor replacement: the new sensor takes over the old sensor’s tag path, so tags, history, and alarms continue. The old sensor is archived with a recorded reason, and its downlinks can be re-sent to the new one.
- Audit log with a configuration screen in Enterprise Management (choose which actions are recorded, 90-day default retention), an event viewer with CSV export, and a Downlinks & Changes tab on each device’s Activity page.
- Commissioning (In testing): a toggle on the device edit page. Devices in testing keep reporting but are excluded from dashboards, health scores, and alarm counts.
- Site maps: every device with an install location shown on a map per site, with a device card and a link to its details.
- Sticky filters: device list filters and search are remembered when you open a device and come back, shown as removable filter chips.
- Device profile Save no longer changes untouched settings, including Fragment Payloads.
- Duplicate DevEUIs are blocked everywhere: an existing or archived DevEUI can no longer be added a second time.
- Accurate alarm counts per site and across the enterprise.
Functional changes
Section titled “Functional changes”Device lists and search
Section titled “Device lists and search”- Added sticky filters. Device list filters and search persist for the session, including after returning from a device page. Active filters show as chips; on a phone the first few are shown with a +N more chip that lists the rest.
- Added a Columns button to the Enterprise device table. Each user chooses the visible columns, and the choice is saved per user.
- Changed device search in Enterprise Management to also match tag path, site, and sensor type.
- Added a Live / In testing filter and a Testing column (also in the Excel export).
- Added an Archived devices button to the Enterprise device table and the Field App device list.
- Changed Clear in the Field App so it clears every filter, including the filter panel toggles.
- Fixed the Field App device list showing a blank “Site:” filter chip at the start of a session; it now shows All sites.
Device details and editing
Section titled “Device details and editing”- Added a Downlinks & Changes tab on the device Activity page, with All / Downlinks / Changes views, a time window, and CSV export. See Downlink history.
- Added a full-screen photo viewer. Tap a device photo to view it, with a Change photo button.
- Changed tag path edits so the Ignition tag moves with the stored path. If the tag cannot be moved, nothing is changed and the device keeps receiving data. See Move and rename tags.
- Changed device edit Save to check each step. A failed save now shows an error and stays on the page instead of returning as if it succeeded.
- Changed the Activity card to list all entries, not just the first ten.
- Fixed device history on phones. The page scrolls to the chart, and value tiles wrap long names instead of cutting them off.
- Fixed activity and MQTT log times shifting by the browser’s time offset.
Archive and replace sensor
Section titled “Archive and replace sensor”- Added Archive Device under Device Actions. Archived devices leave device lists and dashboards but keep their history, and can be un-archived at any time.
- Added the Archived Devices page, with filters for site, replaced or archived, reason, period, and archived by. Each row offers Open device, Open successor, and Un-archive, plus CSV export.
- Added Un-archive. If the device’s tag path was handed to a replacement, you choose a new tag path, with a suggested one offered.
- Added an archived banner on the device page (“Replaced by …” or “This sensor is archived”), with links to the new device and to un-archive.
- Changed Replace device into a four-step Replace sensor flow:
- Find the new sensor, optionally limited to the same type and site, or add one.
- Review what carries over.
- Give a reason (Failed, Battery, Damaged, Upgrade, Other).
- Run the swap, with each step’s status and a retry.
- Changed replacement so the new sensor takes over the old sensor’s tag path. Tags, history, and alarms continue, and name, description, metadata, install location, and photo are copied.
- Added Previous device’s downlinks on a replacement device. It lists the earlier sensor’s downlinks so selected commands can be re-sent to the new sensor.
See Swap a device.
Commissioning (In testing)
Section titled “Commissioning (In testing)”- Added an In testing (commissioning) toggle on the device edit page. New devices start live.
- Devices in testing report normally and their own pages show live status. Dashboards, KPIs, health scores, battery and signal distributions, offline and decode-error counts, and alarm counts exclude them.
- Added an In testing badge in the device header, a banner on the device page, and a chip on Field App device cards.
Adding devices and bulk upload
Section titled “Adding devices and bulk upload”- Changed every add path so a DevEUI that already exists, active or archived, cannot be added again. This covers single add, the add wizard, the Field App, bulk upload, and Replace sensor. Previously a re-add could silently overwrite the existing device; now the message names the existing device and says to open or un-archive it.
- Added a bulk upload preview check that flags rows whose DevEUI already exists. Those rows are skipped.
- Changed the Field App to open the new device’s page after a successful add.
- Added Enter to step through the add-device wizard. Enter on the last step does not save.
- Changed the bulk upload template to the fields SiteSync uses:
dev_eui,join_eui,app_key,name,deviceType,tag_path,description. Serial number, location, and firmware/hardware version were removed. - Changed the already-registered dialog: Sync Again is now Open Device.
- Fixed the Field App add form staying stuck on its loading message after an error.
Dashboards and health
Section titled “Dashboards and health”- Fixed alarm counts. Each site counts only the alarms of its own devices, and the enterprise total was previously inflated by the number of sites. Archived and in-testing devices are excluded.
- Added sensor type and location description to Needs Attention rows. Needs Attention search also matches site and location.
- Added the sensor dashboard’s Health tab.
- Fixed multi-word sensor types (for example “Valve Position”) opening an empty page, and the sensor page keeping the previous type’s list when switching types.
- Changed the launch page MQTT status to show live connection state (Connected / Disconnected / “n of m connected”).
- Changed the Site Health layout so the health score is a KPI tile and tiles wrap on narrow screens.
Site maps
Section titled “Site maps”- Added a site map in Enterprise Management and the Field App. Each device with an install location is a pin colored by status. The map has a searchable device list, Show all, Show my location, and a device card with a link to its details.
- Added View Map buttons on site cards.
See Site map.
Audit log
Section titled “Audit log”Added the SiteSync audit log. It records the user, target, and a readable before/after for:
- device changes: add, bulk upload, edit, rename, tag path, move, photo, replace, archive, delete, export
- downlinks
- device profile, decoder, and UDT changes
- connection and MQTT changes
- site and RBAC changes
- sign-in/out and session start/end
Added Settings › Audit Log, with an on/off switch, a choice of which actions are recorded, profile status, Verify profile and Send test event, and an event viewer with search and CSV export. Retention defaults to 90 days.
See Audit logging and Auditable actions.
Device profiles
Section titled “Device profiles”- Fixed profile Save changing fields the user had not changed, including Fragment Payloads, fragmented ports, and reassembler. Save waits until the profile has loaded and writes only changed fields.
- Fixed display values pointing every device of a profile at one device’s tags, which caused duplicate or inconsistent display values.
- Fixed setting a profile’s primary value, which was not being saved.
- Fixed saving profiles whose UDT inherits from another type.
- Fixed the value pickers on a profile with no UDT; they now explain that a UDT must be assigned first. See Assign a UDT.
- Added “Valve Position” as a sensor type.
- Changed the Actility device profile search panel to a cleaner layout with a close button.
Connections
Section titled “Connections”- Fixed MQTT topics being saved against the wrong connection, and a failed MQTT start showing a success message.
- Fixed connection rename reporting success when it had failed.
Navigation and interface
Section titled “Navigation and interface”- Fixed the blank white panel that appeared on the left behind popups and loading messages.
- Fixed the navigation panel switching between full and compact layouts while a page loads.
- Fixed clipped button shadows on the Device Actions card.
Behavior changes to note
Section titled “Behavior changes to note”| Area | What changes |
|---|---|
| Field App sign-in | The Field App now requires sign-in. |
| Alarm totals | Enterprise alarm totals will be lower than before, because the old total was multiplied by the number of sites. |
| In testing devices | Devices in testing do not appear in dashboard counts or alarm counts. |
| Archived devices | An archived device stays on the network server and keeps receiving data. Delete it to stop that. |
| Log times | Activity and log times may move by the time-zone offset, because they are now read correctly as UTC. |
Requirements
Section titled “Requirements”- SiteSync module. Install the SiteSync module release that accompanies 1.1.0 before importing the projects. Archive, Replace sensor, downlink history, and the audit log depend on it; the projects degrade gracefully on an older module, except Replace sensor.
- Columns. The
User_Preferencesdatabase connection is needed to save each user’s column choices. - Site maps. The site map loads map tiles from
tile.openstreetmap.org, so users’ browsers need access to it. See Ports and network requirements. - Gateway tags. Configuration tags for commissioning, the audit log, and customizations are created automatically under
[default]SiteSync/.
Known limitations
Section titled “Known limitations”- Gateways are not yet shown on the site map.
- The Alarms tab on the sensor dashboard lists all active alarms, including those of archived and in-testing devices; dashboard alarm counts exclude them.
Upgrade instructions
Section titled “Upgrade instructions”Follow Upgrade Enterprise, then run Post-upgrade validation.