Skip to content

Troubleshooting overview

Applies to SiteSync StandardEnterprise ManagementField App Introduced in 1.0.0

SiteSync continuously monitors your fleet and surfaces problems as they arise. Start here to orient, then jump to the specific problem.

Statuses are mutually exclusive (see Health metrics):

  • Online — reporting normally.
  • Never Activated — added but has not yet joined the network.
  • Missed Check-in — has not checked in within its expected interval (formerly “Offline”).
  • Decode Error — messages arrive but can’t be decoded.
  • Other — any remaining state.

Battery and signal are separate flags layered on top — a device can be Online and still flagged Needs Attention.

  1. Open the device page and read the Status panel and Alerts.
  2. For “not reporting” problems, open View Full Diagnostics and read the Communication Flow left to right.
  3. Match your symptom below.
SymptomLikely layerFirst checkGuide
Never ActivatedDevice or network serverJoin credentials and activationDevice never activated
Missed Check-inRadio, power, or intervalLast Seen vs expected intervalDevice missed check-in
Decode ErrorDecoder or profileDecoder assignment and payloadDecode error
MQTT disconnectedInfrastructureBroker reachability and credentialsMQTT disconnected
Downlink queuedDevice class or uplink timingDevice class and latest uplinkDownlink remains queued
Was this page helpful? Report incorrect documentation Last reviewed 2026-07-30